{"id":15624,"date":"2025-09-08T09:01:18","date_gmt":"2025-09-08T00:01:18","guid":{"rendered":"https:\/\/blog.agentsoft.co.kr\/index.php\/2025\/09\/08\/15624\/"},"modified":"2025-09-08T09:01:18","modified_gmt":"2025-09-08T00:01:18","slug":"report-about-control-valve-simulation-%ea%b3%b5%ec%a0%95%ec%a0%9c%ec%96%b4-%ec%bb%a8%ed%8a%b8%eb%a1%a4-%eb%b2%a8%eb%b8%8c-%eb%b3%b4%ea%b3%a0%ec%84%9c","status":"publish","type":"post","link":"https:\/\/blog.agentsoft.co.kr\/index.php\/2025\/09\/08\/15624\/","title":{"rendered":"Report about Control valve simulation (\uacf5\uc815\uc81c\uc5b4 \ucee8\ud2b8\ub864 \ubca8\ube0c \ubcf4\uace0\uc11c)"},"content":{"rendered":"<p><img decoding=\"async\" src=\"https:\/\/image4.happycampus.com\/Production\/thumb212\/2024\/02\/16\/data29461745-0001.jpg\"><img decoding=\"async\" src=\"https:\/\/image4.happycampus.com\/Production\/thumb212\/2024\/02\/16\/data29461745-0002.jpg\"><\/p>\n<p><strong>\ubaa9\ucc28<\/strong><\/p>\n<p>1.\tInherent, valve\uc758 type\uc5d0 \ub530\ub978 Flowrate \ubcc0\ud654<br \/>\n2.\tInherent valve characteristic \uacfc installed valve characteristic\uc758 \ucc28\uc774<br \/>\n3.\tInstalled, valve\uc758 type\uc5d0 \ub530\ub978 Flowrate \ubcc0\ud654<br \/>\n4.\tRangerbility, R \uc640 Valve Coeff, Cv\uc758 \uc601\ud5a5<\/p>\n<p><strong>\ubcf8\ubb38\ub0b4\uc6a9<\/strong><\/p>\n<p>\uacf5\uc555\uc2dd \uc81c\uc5b4\ubc38\ube0c\ub97c \uc124\uacc4\ud558\ub294 \ub370 \uc788\uc5b4\uc11c, \ubcc0\uc218\ub098 \uc870\uac74\uc744 \ub2ec\ub9ac\ud558\uc5ec installation\ud558\uace0 \uc5bb\uc740 \uac12\uc744 \ubcf4\uace0\uc11c\ub85c \uc791\uc131\ud558\uc600\ub2e4.  Pneumatic Control valve\ub294 \uc804\uae30\uc801\uc2e0\ud638(mA)\ub97c \ubb3c\ub9ac\uc801 \ubcc0\ud654(Valve \uc870\uc808)\ub97c \ud1b5\ud574 \uc6d0\ud558\ub294 Flowrate\ub97c \uc5bb\ub3c4\ub85d \ud558\ub294 Valve+Actuator\uc774\ub2e4.<br \/>\n  \ubcf4\ud1b5 Pneumatic Control valve\ub294 3~15psig\uc758 \uc2e0\ud638\ub97c \uc0ac\uc6a9\ud558\ubbc0\ub85c, I\/P transmitter\uac00 4~20mA\uc758 \uc804\uae30\uc2e0\ud638\ub97c 3~15psig\uc758 \uc555\ub825\uc2e0\ud638\ub85c \ubcc0\ud654\ud574\uc11c control valve\uc5d0 \uc804\ud55c\ub2e4\uace0 \uc124\uc815\ud55c\ub2e4.<\/p>\n<p>1.\tInherent, valve\uc758 type\uc5d0 \ub530\ub978 Flowrate \ubcc0\ud654<br \/>\n(a)\tlinear type [\uadf8\ub9bc1] \u2013 linear valve type installation<\/p>\n<p>Inherent Linear type valve\uc758 \uacbd\uc6b0 12mA\uc758 \uc2e0\ud638\ub97c \uc8fc\uc5c8\uc744 \ub54c \uadf8\uc5d0 \ub9de\ub294 9 psig\uc758 \uc2e0\ud638\ub85c valve\ub97c \uc5f4\uc5c8\ub2e4. Command signal-Flowrate\uc758 \ubcc0\ud654 \uc591\uc0c1\uc740 \uc120\ud615\uc744 \ubcf4\uc600\uc73c\uba70 \uc911\uac04 \uac12\uc758 \uc804\uae30\uc2e0\ud638\ub97c \uc8fc\uc5c8\uc744 \ub54c 25l\/min\uc758 \uc720\ub7c9\uc744 \ubcf4\uc5ec\uc8fc\uba70, \uc120\ud615\uc801\uc778 \ud615\ud0dc\ub85c \uc720\ub7c9\uc870\uc808\uc774 \ud544\uc694\ud55c \uc0c1\ud669\uc5d0 \uc801\ud569\ud55c type\uc784\uc744 \uc54c \uc218 \uc788\uc5c8\ub2e4.<\/p>\n<p>\ucd9c\ucc98 : <a href=\"https:\/\/www.happycampus.com\/report-doc\/29461745\/\" target=\"_blank\">\ud574\ud53c\ucea0\ud37c\uc2a4<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\ubaa9\ucc28 1. Inherent, valve\uc758 type\uc5d0 \ub530\ub978 Flowrate \ubcc0\ud654 2. Inherent valve characteristic \uacfc installed valve characteristic\uc758 \ucc28\uc774 3. Installed, valve\uc758 type\uc5d0 \ub530\ub978 Flowrate \ubcc0\ud654 4. Rangerbility, R \uc640 Valve Coeff, Cv\uc758 \uc601\ud5a5 \ubcf8\ubb38\ub0b4\uc6a9 \uacf5\uc555\uc2dd \uc81c\uc5b4\ubc38\ube0c\ub97c \uc124\uacc4\ud558\ub294 \ub370 \uc788\uc5b4\uc11c, \ubcc0\uc218\ub098 \uc870\uac74\uc744 \ub2ec\ub9ac\ud558\uc5ec installation\ud558\uace0 \uc5bb\uc740 \uac12\uc744 \ubcf4\uace0\uc11c\ub85c \uc791\uc131\ud558\uc600\ub2e4. Pneumatic Control valve\ub294 \uc804\uae30\uc801\uc2e0\ud638(mA)\ub97c \ubb3c\ub9ac\uc801 \ubcc0\ud654(Valve \uc870\uc808)\ub97c \ud1b5\ud574 \uc6d0\ud558\ub294 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[749,18749,20607,20608,20609],"class_list":["post-15624","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-749","tag-18749","tag-20607","tag-20608","tag-20609"],"_links":{"self":[{"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/posts\/15624","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/comments?post=15624"}],"version-history":[{"count":0,"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/posts\/15624\/revisions"}],"wp:attachment":[{"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/media?parent=15624"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/categories?post=15624"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/tags?post=15624"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}