{"id":15625,"date":"2025-09-08T09:01:19","date_gmt":"2025-09-08T00:01:19","guid":{"rendered":"https:\/\/blog.agentsoft.co.kr\/index.php\/2025\/09\/08\/15625\/"},"modified":"2025-09-08T09:01:19","modified_gmt":"2025-09-08T00:01:19","slug":"report-about-csth-simulation-%ea%b3%b5%ec%a0%95%ec%a0%9c%ec%96%b4-csth-%ec%8b%9c%eb%ae%ac%eb%a0%88%ec%9d%b4%ec%85%98-%eb%b3%b4%ea%b3%a0%ec%84%9c","status":"publish","type":"post","link":"https:\/\/blog.agentsoft.co.kr\/index.php\/2025\/09\/08\/15625\/","title":{"rendered":"Report about (CSTH) simulation (\uacf5\uc815\uc81c\uc5b4 CSTH \uc2dc\ubbac\ub808\uc774\uc158 \ubcf4\uace0\uc11c)"},"content":{"rendered":"<p><img decoding=\"async\" src=\"https:\/\/image4.happycampus.com\/Production\/thumb212\/2024\/02\/16\/data29461747-0001.jpg\"><img decoding=\"async\" src=\"https:\/\/image4.happycampus.com\/Production\/thumb212\/2024\/02\/16\/data29461747-0002.jpg\"><\/p>\n<p><strong>\ubaa9\ucc28<\/strong><\/p>\n<p>1.\tDV, MV change and response of CSTH process in MAN Mode and basis understanding<br \/>\n2.\tAutomatic process response of CSTH process in free mode<br \/>\n3.\tPreset Mode simulation Before making a change and results analysis<br \/>\n4.\toffset and P mode, PI, PID<br \/>\n5.\tReset &#8211; wind up<\/p>\n<p><strong>\ubcf8\ubb38\ub0b4\uc6a9<\/strong><\/p>\n<p>Continuous stirred tank heater (CSTH) open loop&#038; closed loop system simulation\uc744 \ud1b5\ud574\uc11c \uac01 \ubcc0\uc218(MV, SP)\ub4e4\uc744 \uc870\uc791\ud558\uba70 \ub098\ud0c0\ub098\ub294 response \ub300\ud55c \uc774\ud574\ub97c \ub192\uc774\uace0, optimum control performance\ub97c \uc704\ud55c tuning parameter\ub97c \ucc3e\uc544\ubcf4\uc790. \uc6b0\uc120 Process Control\uc758 \ub300\ud55c \uc774\ud574\ub97c \uc704\ud574 process\uc5d0 \ub300\ud55c \uac12\uc744 \ub2e4\uc74c\uacfc \uac19\uc774 \uc694\uc57d\ud55c\ub2e4.<br \/>\nProcess information &#8211; CSTH, FOPDT model, Feed flow rate=10kg\/min, Cp=0.584kw\/\u2103 (55\u2103 \uc774\ud6c4, \uc628\ub3c4\uc778 20\u2103\ubd80\ud130 \uc815\uc0c1\uc0c1\ud0dc\uc778 55\u2103\uae4c\uc9c0 \uac00\uc5f4\ud560 \ub54c 24.5kw\uc758 \uc5f4\uc774 \uc18c\uc694)<\/p>\n<p>1.\tDV, MV change and response of CSTH process in MAN Mode and basis understanding<br \/>\nDV, MV, SP\ub97c \uc870\uc808\ud558\uae30\uc804 \uac01 % of Unit \uc740 [\uadf8\ub9bc1]\uacfc \uac19\ub2e4. \uc774\ub97c \uc644\uc804\ud55c steady-state\ub85c \uc774\ud574\ud560 \uc218 \uc788\ub2e4. MAN mode\ub85c MV\ub97c \uc218\ub3d9\uc73c\ub85c 10% \uc99d\uac00 \ud6c4 \ub2e4\uc2dc \uc6d0\uc0c1\ubcf5\uadc0\ud558\ub294 \uc2dd\uc73c\ub85c<\/p>\n<p>[\uadf8\ub9bc 1] MV\uc870\uc808 \uc804, MV 10% change\ub97c \uc92c\uc744 \ub54c, response 1,2,3<br \/>\n\uc2dd\uc73c\ub85c \uc870\uc808\ud588\uc744 \ub54c \uc5b4\ub5bb\uac8c response\uac00 \ubc18\uc751\ud558\ub294\uc9c0 \ubcfc \uc218 \uc788\uc5c8\ub2e4. CV\ub294 oscillation \uacfc overshooting\uc5c6\uc774 MV \ubcc0\ud654\uac12\uc5d0 \ub9de\ucdb0 \ubc18\uc751\ud558\uc600\ub2e4. \ud558\uc9c0\ub9cc \uc644\ubcbd\ud558\uac8c MV\uc5d0 \uc6c0\uc9c1\uc784\uacfc \uac19\uc774 PV\uac00 \uce21\uc815\uac12\uc774 \ub098\ud0c0\ub0ac\ub2e4\uace0 \ubcfc \uc218 \uc5c6\ub2e4. Eng. Unit\uc744 \ubcf4\uba74 \uc57d 2%\uc758 \ucc28\uc774\ub97c \ubcf4\uc600\uc74c\uc744 \uc54c \uc218 \uc788\uc5c8\ub2e4. \ub610\ud55c \uc218\ub3d9\uc73c\ub85c \uac12\uc744 \uc870\uc808\ud558\ub294 \uac83\uc740 \uc815\ud655\ud55c % \ubbf8\uc138\ud55c \uc870\uc808\uc5d0 \uc624\ub958\uac00 \uc788\uc5c8\uc73c\uba70, MV\uac00 \uc870\uc808\ub418\ub294 \uc18d\ub3c4\uac00 \ubd88\uc548\uc815\ud558\ub294 \ub4f1\uc744 response moving\uc744 \ud1b5\ud574 \uc54c \uc218 \uc788\uc5c8\ub2e4.<br \/>\n[\uadf8\ub9bc2] DV 5\u2103 \uc870\uc808\uc5d0 \ub530\ub978 response \ubcc0\ud654\uc640 DV, SP, MV data, Eng.Unit<br \/>\n\ub2e4\uc74c\uc73c\ub85c\ub294 Feed temperature\uc744 5\u2103\uc529 \ub450 \ubc88 \uc0c1\uc2b9\uc2dc\ucf30\ub2e4. MV\ub294 Feed \uc628\ub3c4\ub97c 20-55 \u2103\uc0ac\uc774\uc5d0\uc11c 1\u2103\ub97c \uc0c1\uc2b9\uc2dc\ud0a4\ub294\ub370 \uc57d 0.7kw\/\u2103\uac00 \ub4e0\ub2e4\uace0 \ucd08\uae30 data\ub97c \ud1b5\ud574\uc11c \uac00\uc815\ud55c\ub2e4.<\/p>\n<p>\ucd9c\ucc98 : <a href=\"https:\/\/www.happycampus.com\/report-doc\/29461747\/\" target=\"_blank\">\ud574\ud53c\ucea0\ud37c\uc2a4<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\ubaa9\ucc28 1. DV, MV change and response of CSTH process in MAN Mode and basis understanding 2. Automatic process response of CSTH process in free mode 3. Preset Mode simulation Before making a change and results analysis 4. offset and P mode, PI, PID 5. Reset &#8211; wind up \ubcf8\ubb38\ub0b4\uc6a9 Continuous stirred tank heater (CSTH) [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[425,20610,749,18749,20607],"class_list":["post-15625","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-12-","tag-csth","tag-749","tag-18749","tag-20607"],"_links":{"self":[{"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/posts\/15625","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/comments?post=15625"}],"version-history":[{"count":0,"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/posts\/15625\/revisions"}],"wp:attachment":[{"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/media?parent=15625"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/categories?post=15625"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.agentsoft.co.kr\/index.php\/wp-json\/wp\/v2\/tags?post=15625"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}